Tektronix GB1400 gigaBERT
Tektronix GB1400 gigaBERT - Bit Error Rate Tester

The GB1400 is a general-purpose 1400 Mb/s bit error rate tester (BERT) built to meet the exacting standards of design engineers who need to verify and characterize high-speed serial data transmission circuits, interfaces and systems. While primarily a lab instrument, the GB1400’s compact design, full computer programmability and relatively light weight also enable it to serve in manufacturing ATE and field test applications.

The quality of a digital link depends on many factors, but everything comes down to the issue of whether the circuit exhibits a satisfactory BER (bit error rate) and has sufficient margin to function under stress conditions.

The GB1400 has all of the features you expect in a general-purpose BERT, and some you expect only in more expensive instruments, such as automated eyewidth measurements at a specified BER, and the ability to accept an external real-time data stream for bit error testing. Also, the GB1400 has options to add advanced features, such as Burst Mode (which also extends external clock range down to 150 kb/s), and a 1-Mbit programmable pattern memory option.

Features

  • Test digital data transmission up to 1400 Mb/s
  • Set Data Rate with 1 kHz resolution
  • Vary Clock and Data timing with 5 pS resolution
  • Phase-Synchronous Clock and Data Edge Tracking
  • 1-Mbit data pattern memory
  • Measure Eye-Width at Specific BER Automatically
  • Auto-Synchronization Rx/Tx Lock-up
  • Front panel or computer control operation

Pattern Generator (GB1400T) Specifications

Frequency Range Internal Clock Source: 1 Mb/s to 1400 Mb/s
External Clock with Burst Mode: 150 kb/s to 1400 Mb/s
Freq. Resolution (Internal Clock) 10 kHz
Clock Output Amplitude 500 mV to 2.0 Vp-p in 50 mV steps
Clock Output Offset -2.0 V to 1.8 V in 50 mV steps
Data Output Amplitude 500 mV to 2.0 Vp-p in 50 mV steps
Data Output Offset -2.0 V to 1.8 V in 50 mV steps
Data Delay Range ±4 ns
Data Delay Increments 5 ps
Clock Delay ±4 ns
Clock Delay 5 ps
PRBS Patterns (2n -1) 7, 15, 17, 20, 23
Burst Mode (ECL levels only) Standard feature

Error Detector ( GB1400R ) Specifications

Specifications

Frequency Range 1 Mb/s to 1400 Mb/s
Frequency Range with Burst Mode 150 kb/s to 1400 Mb/s
Burst Mode (ECL levels only) Standard feature
Clock Input Levels (max) 500 mV to 1.5 Vp-p
Clock Input Terminations GND, AC, -2 V p-p
Clock Input Threshold Fixed Input Threshold
Data Input Levels (max) 500 mV to 1.5 Vp-p
Data Input Threshold 1.00 to +1.50 V in 50 mV steps
Data Input Terminations GND, AC, -2 V
Single ended or differential operation for clock and data inputs

Options

  • 02: 75 ohm
  • 05: Burst Mode

Please contact us for more information on the Tektronix GB1400 gigaBERT


Haefely
ECOMPACT4

Haefely Ecompact 4
CA Instruments
5001ix


California Instruments 5001ix
Voltech
PM6000

Voltech PM6000
IFI
T4026-40

IFI T4026-40

Teseq
NSG437
Varian 956 Porta Test
Solar
2654-1

Solar 2654-1
Terms & Conditions Privacy Notice Site Map Terms of Use
 
Copyright © 1996-2008  |  Advanced Test Equipment Rentals  |  All Rights Reserved