| Power Output |
1500 VA at 130 to 110 volts rms output with power factor of unity to ±0.7 |
| Output Voltage Ranges |
0 to 32.5 volts rms |
| 0 to 65 volts rms |
| 0 to 130 volts rms |
| 0 to 260 volts rms |
| Total Harmonic Distortion |
less than 0.3% distortion at midband (200 to 600 Hz) |
| less than 0.5% distortion from 45 Hz to 5 kHz |
| Amplitude Stability |
±0.25% for 24 hours at constant line, load and ambient temperature conditions |
| Load Regulation |
±1% over the range from 45 Hz to 5 kHz when tested at unity power factor |
| Full Power Frequency Range |
45 Hz to 5 kHz |
| AC Input Line |
210 to 250 volts rms |
| Unit may be wired for the following single phase voltages on special order: |
115 VAC, 208 VAC, 220 VAC and 240 VAC |
| AC Input Frequency |
48 to 65 Hz |
| AC Input Power |
5000 Watts maximum under worst case line and full rated worst case load conditions |
| Dimensions (H x W x D) |
14" x 19" x 21" |
| Approx. shipping weight |
210 lbs. |